FTTX Handheld OTDR SM Dual Wavelengths OTDRs
กดเพื่อขยายขนาด |
|
SM Dual Wavelengths OTDRs
Featrues:
- SM/MM models available
- Dynamic range selectable: up to 45dB
- Quick startup: <5 seconds
- Hotkey feature: easy operation, events review and analysis
- TraceManager software: easy batch editing and single-page multi-trace printing
- Visible fault locator: fast locating failures anywhere in the network
- Enhanced power performance: up to 8 hours continuous operation with one charge
- Handy and smart: only 1kg (2.2 lbs)
- Safe and solid: 2-meter drop test passed
Description :
Compared with other OTDRs, SUN-OT5000 Handheld OTDR Series is more compact and user-friendly. The hotkey feature enables convenient events review and analysis. SUN-OT5000 Handheld OTDR Series supports averaging and real-time test on single-mode (1310/1490/1550/1625nm) fibers and complies with various connector types. SUN-OT5000 Single Mode Dual Wavelengths OTDRs include SUN-OT5000-S2, SUN-OT5000-S3 and SUN-OT5000-S4. With “TraceManager” software, you can download trace files from OTDR to PC for further analysis, reporting and printing.
Specification :
Note:
(1) Specifications describe the instrument’s warranted performance, measured with typical PC-type connectors. Uncertainties due to the refractive index of fiber are not considered;
(2) The dynamic range is measured at maximum pulse width within average time of 3 minutes;
(3) Among the selectable ranges 160km and 240km are only for SUN-OT5000-S2 and SUN-OT5000-S3; 120Km is only for SUN-OT5000-M;
(4) Among the pulse widths, 5ns, 10ns, 300ns, 10us and 20us are only available for SUN-OT5000-S2 and SUN-OT5000-S3; 12ns and 275ns are only for SUN-OT5000-M;
(5) Conditions for dead zone measurement: for SUN-OT5000-M, reflection events are within a range of 2.1Km, reflection intensity is less than -35dB, measured at pulse width of 30ns; For SUN-OT5000-S2 and SUN-OT5000-S3, reflection events are within a range of 0.6Km, reflection intensity is less than -45dB, measured at pulse width of 10ns (event dead zone) and 30ns (attenuation dead zone);
(6) Conditions for dead zone measurement: when reflection events are within a range of 1km, reflection intensity is less than -32dB; and the dead zone is measured at pulse width of 12ns.
Ordering Information
Application
- Measure the length of optical fiber and cable
- Measure the distance between two points on optical fiber and cable
- Locate faults and ruptures of optical fiber and cable
- Display distribution curve of optical fiber and cable loss
- Measure attenuation coefficient of optical fiber and cable
- Measure loss between two points on optical fiber and cable
- Measure loss of tie-ins
- Measure reflection of reflection events of optical fiber and cable
กำหนดส่งสินค้า : 5 - 7 วัน